UTRED-16 KIT
|
UTRED30-16 SINGLE CHANNEL KIT
|
UTRED30-16 – DUAL CHANNEL KIT
|
UTRED30-WiFi SINGLE CHANNEL KIT
|
UTRED30-WiFi DUAL CHANNEL KIT
|
External Sensor Measurement Range |
-40°C to +99°C (-40°F to +210°F) | -40°C to +99°C (-40°F to +210°F) | -40°C to +99°C (-40°F to +210°F). | -40°C to +99°C (-40°F to +210°F). | -40°C to +99°C (-40°F to +210°F). |
Operating Temperature Range |
-30°C to +60°C (-22°F to +140°F). | -30°C to +60°C 0 – 99 % RH (non-condensing) | -30°C to +60°C 0 – 99 % RH (non-condensing) | -30°C to +60°C (-22°F to +140°F). | -30°C to +60°C (-22°F to +140°F). |
Storage Temperature Range |
0°C to +40°C (32°F to +104°F). | -10°C to +40°C (32°F to +104°F) | -10°C to +40°C (32°F to +104°F). | -10 °C to +40 °C (32 °F to +104 °F). | -10 °C to +40 °C (32 °F to +104 °F). |
Rated Temperature Reading Accuracy (Low) |
Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F). Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F). | Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F) Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F) |
Rated Temperature Reading Accuracy (High) |
Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). | Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). | Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). | Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F). Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F). | Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F) Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F) |
Rated Temperature Reading Resolution |
Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F). Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F). Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F). | Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F). Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F). Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F). | Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F). Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F). Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F). | 0.1°C or 0.1°F. | Better than 0.1°C (0.2°F) for -30°C to +60°C (-22°F to +140°F). Better than 0.2°C (0.4°F) for -40°C to -30°C (-40°F to -22°F). Better than 0.5°C (0.9°F) for +60°C to +99°C (+140°F to +210°F). |
Recording Capacity |
16,129 temperature readings. 112 days @ 10min logging, 168 days @ 15min logging. Statistics memory (for display on LCD): Max/Min values and alarm duration values. | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics. | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics. | 16,129 temperature readings. 67 days at 6 minute logging.Day summary statistics memory (for display on LCD): up to 30 days of Min/ Max/duration and alarm trigger statistics. | 32,000 total log memory. Provides 16,000 temperature readings per channel. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics. |
Battery Life |
1 year storage, 2 years of normal use (based on 15 minute logging, download data monthly). | AAA battery up to 12 months – if unit is operated without power supply. | AAA battery up to 12 months – if unit is operated without power supply. | Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months | Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months |